Šiaip pastebėjimas - bendras vardiklis yra "Check/Repair Wiring and Connectors". Aš tai pats paieškočiau, kur kontaktai dingo. Gal užtektų tik paklibint jungtis. On 07/17/2013 10:25 PM, md wrote: > Gla zinote kas galetu pataisyti klima. Saldo, sildo, bet jauciasi, kad > kartais grybauja - tai pucia, tai nustoja pusti. > > Karutis - Seat Ibiza > > Klaidos, kurias pavyko nuskaityti klimos ekrane: > > 01271 - Positioning Motor for Temperature Flap (V68): Faulty > Possible Causes > • Wiring/Connectors from/to Positioning Motor for Temperature Flap (V68) > faulty > • Positioning Motor for Temperature Flap (V68) blocked > • Positioning Motor for Temperature Flap (V68) faulty > Possible Solutions > • Check Positioning Motor for Temperature Flap (V68) > ◦ See Measuring Value Blocks (MVB) > ◦ Perform Output Test > ◦ Perform Basic Setting > • Check/Repair Wiring and Connectors > > -------------------------------------------------------------------------- > > 01274 - Air Flow Flap Positioning Motor (V71): Faulty > Possible Causes > • Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) faulty > • Positioning Air Flow Flap Positioning Motor (V71) blocked > • Positioning Air Flow Flap Positioning Motor (V71) faulty > Possible Solutions > • Check Air Flow Flap Positioning Motor (V71) > ◦ See Measuring Value Blocks (MVB) > ◦ Perform Output Test > ◦ Perform Basic Setting > • Check/Repair Wiring and Connectors > > -------------------------------------------------------------------------- > > 01273 - Fresh Air Blower (V2) > Possible Causes > • Fresh Air Blower (V2) defective > • Control Module for Fresh Air Blower (J126) defective > • Short of open circuit in wiring to Fresh Air Blower (V2) > • Climatronic Control Module (J255) malfunctioning > Possible Solutions > • Check Fresh Air Blower (V2) > ◦ Perform Output Test (Check Air Vents while Blower is active) > ◦ Check Meas. Blocks while Blower is active > • Check Control Module for Fresh Air Blower (J126) > ◦ Perform Output Test (Check Air Vents while Blower is active) > • Check wiring and connectors > > -------------------------------------------------------------------------- > > 00457 - Control Module for Network (J519): No Signal/Communication > Possible Symptoms > • Reduced Functionality > Possible Causes > • Communication from/to Control Module for Network (J519) faulty > • Wiring/Connectors from/to Control Module for Network (J519) faulty > Possible Solutions > • Check Communication from/to Control Module for Network (J519) > ◦ See Measuring Value Blocks (MVB) > • Check Wiring/Connectors from/to Control Module for Network (J519) > Special Notes > • Intermittent Fault Codes may be ignored as long as no Functional > Problems are experienced.