Šiaip pastebėjimas - bendras vardiklis yra "Check/Repair Wiring and 
Connectors".

Aš tai pats paieškočiau, kur kontaktai dingo. Gal užtektų tik paklibint 
jungtis.

On 07/17/2013 10:25 PM, md wrote:
> Gla zinote kas galetu pataisyti klima. Saldo, sildo, bet jauciasi, kad
> kartais grybauja - tai pucia, tai nustoja pusti.
>
> Karutis - Seat Ibiza
>
> Klaidos, kurias pavyko nuskaityti klimos ekrane:
>
> 01271 - Positioning Motor for Temperature Flap (V68): Faulty
> Possible Causes
> • Wiring/Connectors from/to Positioning Motor for Temperature Flap (V68)
> faulty
> • Positioning Motor for Temperature Flap (V68) blocked
> • Positioning Motor for Temperature Flap (V68) faulty
> Possible Solutions
> • Check Positioning Motor for Temperature Flap (V68)
> ◦ See Measuring Value Blocks (MVB)
> ◦ Perform Output Test
> ◦ Perform Basic Setting
> • Check/Repair Wiring and Connectors
>
> --------------------------------------------------------------------------
>
> 01274 - Air Flow Flap Positioning Motor (V71): Faulty
> Possible Causes
> • Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) faulty
> • Positioning Air Flow Flap Positioning Motor (V71) blocked
> • Positioning Air Flow Flap Positioning Motor (V71) faulty
> Possible Solutions
> • Check Air Flow Flap Positioning Motor (V71)
> ◦ See Measuring Value Blocks (MVB)
> ◦ Perform Output Test
> ◦ Perform Basic Setting
> • Check/Repair Wiring and Connectors
>
> --------------------------------------------------------------------------
>
> 01273 - Fresh Air Blower (V2)
> Possible Causes
> • Fresh Air Blower (V2) defective
> • Control Module for Fresh Air Blower (J126) defective
> • Short of open circuit in wiring to Fresh Air Blower (V2)
> • Climatronic Control Module (J255) malfunctioning
> Possible Solutions
> • Check Fresh Air Blower (V2)
> ◦ Perform Output Test (Check Air Vents while Blower is active)
> ◦ Check Meas. Blocks while Blower is active
> • Check Control Module for Fresh Air Blower (J126)
> ◦ Perform Output Test (Check Air Vents while Blower is active)
> • Check wiring and connectors
>
> --------------------------------------------------------------------------
>
> 00457 - Control Module for Network (J519): No Signal/Communication
> Possible Symptoms
> • Reduced Functionality
> Possible Causes
> • Communication from/to Control Module for Network (J519) faulty
> • Wiring/Connectors from/to Control Module for Network (J519) faulty
> Possible Solutions
> • Check Communication from/to Control Module for Network (J519)
> ◦ See Measuring Value Blocks (MVB)
> • Check Wiring/Connectors from/to Control Module for Network (J519)
> Special Notes
> • Intermittent Fault Codes may be ignored as long as no Functional
> Problems are experienced.