Tema: Re: Q: dėl signalizacijos
Autorius: Night
Data: 2009-03-03 14:27:56
Nu tu duodi - kokia signalizacija, parasyk gal :) Pagal 5 koda speju, kad DSC, taigi jei sugebejai 
isskaityti, kad gedimo kodas 5, reikejo dar karta 5 paspausti ir papatytum, apie kuria zona kalba. 
Kadangi pajungta be varzu - priezasties nenuspesiu. Jei butu su double end of line resistors - reisktu 
kad grandineje trumpas. Manual'as raso dar kazkokiu ten briedu - paskaityk pats. Jei signa ne DCS - 
sorry - pats kaltas, kad neparasei :)

Zone Fault (including Fire Zone): A zone on the system is experiencing trouble, meaning that a zone 
could not provide an alarm to the panel if
required to do so (e.g. a fire zone is open, or there is a short on a DEOL zone, or a supervisory fault 
on a wireless zone). When a zone fault occurs,
the keypad(s) on the system will start to beep. Press [5] while in Trouble mode to view the affected 
zones.
NOTE: A Fire zone trouble will be generated and displayed in the armed state.

"Aidas" <aidas021@hotmail.com> wrote in news:goj3gd$5ga$1@trimpas.omnitel.net:

> Sveiki
> Prad?jo durniuot signalizacija.
> Ima "pyps?t" ir u˛sidega geltona lampe?ka - atseit gedimas. Jokio zonos
> suveikimo nerodo. Ta geltona lampe?ka tai tiesiog ant aki? u˛sidega ir
> u˛gesta.
> Klaidos rodo Nr.5 - Spindulio grandin?s gedimas
> Kaip surasti kurio spindulio ?ia gedimas ?
> Tiesa pajungta be var˛?, papras?iausias variantas. NC
> 
> 
> 
>