Independent park heating/auxiliary heating with/without telestart
Independent park heating/auxiliary heating with/without telestart
Functions
Independent park heating mode is activated by way of preprogramming at the
multi-information display, on-board monitor or via telestart (remote control
of independent park heating) and heats up the engine and interior
compartment.
Additional heater
The functions telestart, preprogramming and operation via MID or on-board
monitor are not available if the independent park heater/auxiliary heater is
programmed to auxiliary heater.
Auxiliary heating mode is started by the heating/air conditioning control
unit if heating is required by the heating/air conditioning system or when
the engine is cold and is controlled, among other things, also by the
independent park heater/auxiliary heater. The coolant temperature is
registered and evaluated by a temperature sensor in the independent park
heater/auxiliary heater and the Y-controlled variable in the heating/air
conditioning control unit. Auxiliary heating mode is not indicated in the
on-board monitor or MID.
Switch-on conditions for the auxiliary heater on the M47, M51, M57 and M67
IHKA E38 - Engine running at coolant temperature <=70°C, no undervoltage
cutout, no fault in auxiliary heater and fault interlock
IHR E39 - Engine running at coolant temperature <=70°C, no undervoltage
cutout, no fault in auxiliary heater and fault interlock
IHKA/R E39 with K-bus - terminal 61, Y>=100%, outside temperature
<=10°C, blower ON, no undervoltage cutout, no fault in auxiliary heater and
fault interlock
IHKA/R E39 without K-bus - terminal 61, Y>=50%, outside temperature
<=10°C, blower ON, no undervoltage cutout, no fault in auxiliary heater and
fault interlock
HS E46 - Engine speed >500 rpm, Y>=50%, blower ON
IHKA E46 - Engine speed >500 rpm, Y>=50%, blower ON
The independent park heater/auxiliary heater (Webasto) features its own
control unit.
The independent park heating/auxiliary heating is activated by the
heating/air conditioning control unit by means of a wake-up line or a
telegram via the K-bus. The independent park heater/auxiliary heater control
unit sends a feedback via the independent park heating feedback line or a
telegram on the K-bus to the heating/air conditioning control unit
indicating whether the auxiliary park heater has switched on.
Heating of the coolant temperature sensor for the DME/DDE (digital motor
electronics, digital diesel electronics) by the independent ark heating
system must be avoided in park heating mode. In order to avoid falsification
of the engine temperature for the DME/DDE, the water circuit is disconnected
by a shut-off valve in the area of the coolant temperature sensor .
Shut-off valve
Whether a shut-off valve is installed depends on the type of engine.
The radio remote control function makes it possible to start the independent
heating from a distance of up to 400 m.
Telestart
The range may be restricted from closed rooms. When operating, the hand-held
transmitter should be held with the antenna pointing upward.
The start procedure is initiated by pressing the left-hand rocker switch.
The LED at the top edge of the hand-held transmitter indicates that the
start signal has been sent (flashes max. 30 minutes = running time of
independent park heating system).
Initialization of hand-held transmitter for telestart:
If a new telestart receiver is installed, the two hand-held transmitters
must be re-initialised.
Interrupt the current supply to the telestart receiver for about 10
seconds by pulling the fuse as shown in the wiring diagram
Re-insert the fuse and within the next 3 seconds, briefly press the OFF
switch on the hand-held transmitter.
Within the next 5 seconds, briefly press the ON switch on the hand-held
transmitter.
The remote control unit is operational after a further 3 seconds.
Briefly press the OFF switch on the hand-held transmitter. The
verification LED stops flashing.
Finally, carry a functional test.
Undervoltage cutout
An adequately charged battery is the basic prerequisite for operation of the
independent park heating system . The undervoltage threshold depends on the
outside temperature and is compared with the terminal 30 voltage applied at
the operating unit. If this voltage at the operating unit drops below the
calculated value, operation of the independent heater is ended.
The independent park heating function can be activated via the on-board
monitor or MID in ignition lock position 1 or via telestart or
preprogramming in ignition lock position 0. Various settings are possible
dependent on the ignition lock position.
Statuses in ignition lock position 1:
Operating unit active
Temperature control adjustable
Flap program adjustable
Blower adjustable
Function lights ON
Buttons for other functions not active (e.g. defrost, heated rear
window, recirculated air/AUC and air conditioning)
Statuses in ignition lock position 0:
Operating unit not active
Temperature control not active (water valves open)
Blower at medium speed
Flap position to defrost and footwell with electrical positioner drive
The shut-off valve is further placed under current during the rinsing phase
and then switches off.