Gla zinote kas galetu pataisyti klima. Saldo, sildo, bet jauciasi, kad kartais grybauja - tai pucia, tai nustoja pusti. Karutis - Seat Ibiza Klaidos, kurias pavyko nuskaityti klimos ekrane: 01271 - Positioning Motor for Temperature Flap (V68): Faulty Possible Causes • Wiring/Connectors from/to Positioning Motor for Temperature Flap (V68) faulty • Positioning Motor for Temperature Flap (V68) blocked • Positioning Motor for Temperature Flap (V68) faulty Possible Solutions • Check Positioning Motor for Temperature Flap (V68) ◦ See Measuring Value Blocks (MVB) ◦ Perform Output Test ◦ Perform Basic Setting • Check/Repair Wiring and Connectors -------------------------------------------------------------------------- 01274 - Air Flow Flap Positioning Motor (V71): Faulty Possible Causes • Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) faulty • Positioning Air Flow Flap Positioning Motor (V71) blocked • Positioning Air Flow Flap Positioning Motor (V71) faulty Possible Solutions • Check Air Flow Flap Positioning Motor (V71) ◦ See Measuring Value Blocks (MVB) ◦ Perform Output Test ◦ Perform Basic Setting • Check/Repair Wiring and Connectors -------------------------------------------------------------------------- 01273 - Fresh Air Blower (V2) Possible Causes • Fresh Air Blower (V2) defective • Control Module for Fresh Air Blower (J126) defective • Short of open circuit in wiring to Fresh Air Blower (V2) • Climatronic Control Module (J255) malfunctioning Possible Solutions • Check Fresh Air Blower (V2) ◦ Perform Output Test (Check Air Vents while Blower is active) ◦ Check Meas. Blocks while Blower is active • Check Control Module for Fresh Air Blower (J126) ◦ Perform Output Test (Check Air Vents while Blower is active) • Check wiring and connectors -------------------------------------------------------------------------- 00457 - Control Module for Network (J519): No Signal/Communication Possible Symptoms • Reduced Functionality Possible Causes • Communication from/to Control Module for Network (J519) faulty • Wiring/Connectors from/to Control Module for Network (J519) faulty Possible Solutions • Check Communication from/to Control Module for Network (J519) ◦ See Measuring Value Blocks (MVB) • Check Wiring/Connectors from/to Control Module for Network (J519) Special Notes • Intermittent Fault Codes may be ignored as long as no Functional Problems are experienced.